3-Monochloropropanediol (3-MCPD) esters and glycidyl esters (GE) are formed as by-products during the refining of edible oils. In the human body, they react to form the known toxins 3-monochloropropanediol (3-MCPD) and glycidol. The European Union has imposed stringent regulations, specifying maximum allowable concentrations of these compounds in food products. In the oil matrix, the compounds are partially present in their ester form. The analysis requires transesterification and derivatization.

The GERSTEL 3-MCPD SamplePrepSolution enables automated determination of 3-MCPD, Glycidol and 2-MCPD following ISO 18363-1, AOCS Cd 29c-13, and DGF C-VI 18 (10), known as the “indirect” methods due to the indirect determination of glycidol. These are the most frequently used methods world-wide and they are practically identical.

In an international round robin organized by the DGF in 2023, the maximum DGF-score of 2 was achieved using the GERSTEL 3-MCPD SamplePrepSolution for all samples and all analysis parameters. For detailed information, please ask your regional GERSTEL contact or send an e-mail to: info@gerstel.de.

Additional automated analysis systems are available from GERSTEL for:
  • The Zwagerman-Overmann  method ISO 18363-4:2021 offers faster analysis and relies on isotope dilution for improved quality control without the need for evaporation or centrifugation.
  • Method ISO 18363-3, AOCS Cd 29a-13, known as the “Unilever” method, which requires a 16h reaction period at sub-ambient temperature.

GERSTEL MPS configurations are available as WorkStation independent of the analysis system or as complete automated analysis system that also performs introduction of the prepared extract to the GC-MS(/MS).

The GERSTEL mVAP evaporates solvent and excess derivatization reagent from up to 6 samples in one batch under controlled vacuum, temperature and agitation for lower limits of determination. Removing residual derivatization reagent by GC column backflush, further improves GC-MS(/MS) system stability and shortens analysis time.

GERSTEL QuickMIX performs extremely efficient mixing for extraction of up to 6 samples in one batch with mixing power comparable to vortex mixers.

Sample Prep and analysis can be performed in parallel (PrepAhead) for optimized system productivity and throughput. As soon as a sample is prepared, the MPS introduces it to the GC-MS(/MS) ensuring that all samples are processed in exactly the same way for improved reproducibility and quality of results. The control software is fully integration.  One method and one sequence table controls both sample preparation and GC-MS/(MS) analysis for the three commonly used methods types.